SMT -
Robotics -
About Us -
Contact Us
Events
News-
Sales Network
The dedicated pulse train control has achieved a compact body and a low price.
The response frequency is enhanced about two times in comparison with former models. The position
setting time of uniaxial robots is reduced by about 40%.Note 1
Note 1. With a 400W servomotor, 20mm ball screw lead, and portability of 40kg.
It is easy to assemble them in automated machinery. You can save much labor in designing, parts selection, setting and more. A large cost reduction is possible.
The compact design has reduced the width up to a maximum of 38% in comparison with former models. In addition, the improvement of radiation efficiency makes it possible to arrange the devices with less space in between. Multiple units can be installed side by side in a neat arrangement.
The parameter settings and fastening-hole pitches are the same as those of former models. It is easy to replace the software and the hardware as well.
You can have analog outputs for speed, amperage, and more information to know the operation status in real time. RDV-Manager, the dedicated support software, is also available for a graphical view of the status.
The full-specification operation is available with a single- phase power supply.
Model | RDV-X | RDV-P | ||||||
Driver model | RDV-X205 | RDV-X210 | RDV-X220 | RDV-P205 | RDV-P210 | RDV-P220 | RDV-P225 | |
Number of controllable axes | Single-axis | |||||||
Controllable robots | Single-axis robot FLIP-X | Linear motor single-axis robot PHASER | ||||||
Basic specifications | ||||||||
---|---|---|---|---|---|---|---|---|
Capacity of the connected motor | 200V 100W or less | 200V 200W or less | 200V 600W or less | 200V 100W or less | 200V 200W or less | 200V 400W or less | 200V 750W or less | |
Maximum power consumption | 0.3kVA | 0.5kVA | 0.9kVA | 0.3kVA | 0.5kVA | 0.9kVA | 1.3kVA | |
Dimensions | W40×H160×D140mm | W40×H160× D170mm |
W40×H160×D140mm | W40×H160× D170mm |
W55×H160× D170mm |
|||
Weight | 0.7kg | 1.1kg | 0.7kg | 1.1kg | 1.2kg | |||
Input power supply | Control power supply | Single phase 200 to 230V +10%, -15%, 50/60Hz +/-5% | ||||||
Motor power supply | Single phase / 3-phase 200 to 230V +10%, -15%, 50/60Hz +/-5% | |||||||
Axis control | ||||||||
Position detection method | Resolver | Magnetic linear scale | ||||||
Control system | Sine-wave PWM (pulse width modulation) | |||||||
Control mode | Position control | |||||||
Maximum speed Note 1 | 5000rpm | 3.0m/s | ||||||
Input/output related function | ||||||||
Position command input | Line driver signal (2M pps or less) (1) Forward pulse + reverse pulse (2) Sign pulse + Command pulse (3) 90-degree phase difference 2-phase pulse command One of (1) to (3) is selectable. | |||||||
Input signal | 24V DC contact point signal input (usable for sink/source) (24V DC power supply
incorporated) (1) Servo ON (2) Alarm reset (3) Torque limit (4) Forward overtravel (5) Reverse overtravel (6) Origin sensorNote 3 (7) Return-to-origin (8) Pulse train input enable (9) Deviation counter clear |
|||||||
Output signal | Open collector signal output (usable for sink/source) (1) Servo ready (2) Alarm (3) Positioning completed (4) Return-to-origin complete |
|||||||
Relay output signal | Braking cancel signal (24V 375mA) | - | ||||||
Position output | Phase A, B signal output: Line driver signal output Phase Z signal output: Line driver signal output / open collector signal output N/8192 (N=1 to 8191), 1/N (N=1 to 64) or 2/N (N=3 to 64) |
|||||||
Monitor output | Selectable items: 2ch, 0 to +/-5V voltage output, speed detection value, torque command, etc. | |||||||
Internal function | ||||||||
Display | 5-digit number indicator, Control power LED | |||||||
External operator | PC software "RDV-Manager" monitoring function, parameter setting function,
operation tracing function, trial operation function, etc. USB2.0 is used. Windows Vista / 7 / 8 / 8.1 personal computer can be connected. |
|||||||
Regenerative braking circuit | Included (but without braking resistor) | |||||||
Dynamic brake Note 4 | Included (Operation conditions can be set.) (No DB resistor, connection: 2-phase short circuit) | Included (Operation conditions can be set.) (with DB resistor, connection: 2-phase short circuit) | ||||||
Protective function Note 2 |
Semi-enclosure type (IP20) | |||||||
Protective functions | Over-current, overload, braking resistor overload, main circuit overvoltage, memory error, etc. | |||||||
Options | ||||||||
Support software for PC | RDV-Manager | |||||||
General specifications | ||||||||
Operating temperature | 0°C to +55°C | |||||||
Storage temperatureNote 5 |
-10°C to +70°C | |||||||
Operating humidity | 20% to 90%RH (non-condensing) | |||||||
VibrationNote 6 | 5.9m/s2(0.6G) 10 to 55Hz |
Note 1. These data are parameters and calculation range in controlling the robot driver and do not indicate the capacity of the robot at the maximum speed.
Note 2. JIS C 0920 (IEC60529) is used as the base for the protection method.
Note 3. GXL-8FB (made by SUNX) or FL7M-1P5B6-Z (made by YAMATAKE) is used for the origin sensor. The power consumption of the origin sensor is 15mA or less (at open output) and only 1 unit of the origin sensor is connected to each robot driver. (future specification)
Note 4. Use the dynamic brake for emergency stop. Note that the braking may be less effective depending on the robot model.
Note 5. The storage temperature is the temperature in the non-energized state including transportation.
Note 6. The JIS C 60068-2-6:2010 (IEC 60068-2-6:2007) test method is uses as the base.